{"id":135,"date":"2015-12-03T03:14:12","date_gmt":"2015-12-03T03:14:12","guid":{"rendered":"http:\/\/emra.com\/wp\/?page_id=135"},"modified":"2016-02-09T02:07:57","modified_gmt":"2016-02-09T02:07:57","slug":"system-balancing-plans","status":"publish","type":"page","link":"https:\/\/www.emra.com\/index.php\/services\/building-operations-efficiency-consulting\/system-balancing-plans\/","title":{"rendered":"System Balancing Plans"},"content":{"rendered":"<div id=\"x-section-1\" class=\"x-section\" style=\"margin: 0px; padding: 45px 0px;  background-color: transparent;\" ><div id=\"\" class=\"x-container   max width\" style=\"margin: 0px auto; padding: 0px; \" ><div  class=\"x-column x-sm x-1-1\" style=\"padding: 0px; \" ><div id=\"\" class=\"x-text\" style=\"\" ><h3>System Balancing Plans<\/h3>\n<p><strong><span style=\"color: #ff6600;\">Multifamily | Commercial | Institutional | Industrial | Government<\/span><\/strong><br \/>\n<a href=\"https:\/\/emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-2-Master-Venting-Plan-pacific-1.jpg\" rel=\"attachment wp-att-832\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-832 alignright\" src=\"https:\/\/emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-2-Master-Venting-Plan-pacific-1-300x247.jpg\" alt=\"system balancing plans 2 - Master Venting Plan (pacific)\" width=\"300\" height=\"247\" srcset=\"https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-2-Master-Venting-Plan-pacific-1-300x247.jpg 300w, https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-2-Master-Venting-Plan-pacific-1-768x631.jpg 768w, https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-2-Master-Venting-Plan-pacific-1-1024x842.jpg 1024w, https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-2-Master-Venting-Plan-pacific-1-100x82.jpg 100w, https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-2-Master-Venting-Plan-pacific-1-862x708.jpg 862w, https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-2-Master-Venting-Plan-pacific-1-1000x822.jpg 1000w, https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-2-Master-Venting-Plan-pacific-1.jpg 1987w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><br \/>\nUneven distribution of heat throughout the building, results in overheating certain parts in order to keep other spaces (apartments, offices) comfortable. In order to address this situation it is necessary to balance the heating distribution system.<\/p>\n<h4><span style=\"color: #ff6600;\"><strong>One Pipe Steam<\/strong><\/span><\/h4>\n<p>On one-pipe steam systems, this is accomplished by properly venting the distribution piping so that air is removed quickly and steam moves evenly to all sections of the building. In order to accomplish this our engineers map of the basement steam distribution system, and develop a customized master venting schedule for your building. The purpose of the Master Venting schedule is to ensure even steam distribution throughout the building.<\/p>\n<h4><span style=\"color: #ff6600;\"><strong><a href=\"https:\/\/emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-1-IR000409_0949-40-5th-Ave-in-room-adjacent-to-boiler-GOOD.jpg\" rel=\"attachment wp-att-710\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-710 alignleft\" src=\"https:\/\/emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-1-IR000409_0949-40-5th-Ave-in-room-adjacent-to-boiler-GOOD-300x300.jpg\" alt=\"system balancing plans 1 - IR000409_0949 (40 5th Ave - in room adjacent to boiler - GOOD)\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-1-IR000409_0949-40-5th-Ave-in-room-adjacent-to-boiler-GOOD-300x300.jpg 300w, https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-1-IR000409_0949-40-5th-Ave-in-room-adjacent-to-boiler-GOOD-150x150.jpg 150w, https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-1-IR000409_0949-40-5th-Ave-in-room-adjacent-to-boiler-GOOD-100x100.jpg 100w, https:\/\/www.emra.com\/wpcontent\/uploads\/2016\/02\/system-balancing-plans-1-IR000409_0949-40-5th-Ave-in-room-adjacent-to-boiler-GOOD.jpg 640w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a>Two Pipe Steam &amp; Hydronic<\/strong><\/span><\/h4>\n<p>On two-pipe steam and hydronic (hot water space) heating systems there are a number of different causes of distribution system imbalance. Our energy professionals will examine your system to determine the root cause and develop plan of action that gets heat to all areas of your building and stops occupants from dumping your fuel dollars out open windows.<\/p>\n<\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":109,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-blank-4.php","meta":{"footnotes":""},"class_list":["post-135","page","type-page","status-publish","hentry","no-post-thumbnail"],"_links":{"self":[{"href":"https:\/\/www.emra.com\/index.php\/wp-json\/wp\/v2\/pages\/135","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.emra.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.emra.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.emra.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.emra.com\/index.php\/wp-json\/wp\/v2\/comments?post=135"}],"version-history":[{"count":8,"href":"https:\/\/www.emra.com\/index.php\/wp-json\/wp\/v2\/pages\/135\/revisions"}],"predecessor-version":[{"id":833,"href":"https:\/\/www.emra.com\/index.php\/wp-json\/wp\/v2\/pages\/135\/revisions\/833"}],"up":[{"embeddable":true,"href":"https:\/\/www.emra.com\/index.php\/wp-json\/wp\/v2\/pages\/109"}],"wp:attachment":[{"href":"https:\/\/www.emra.com\/index.php\/wp-json\/wp\/v2\/media?parent=135"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}